What is the capacitance of an elevator power cable?

If you’ve ever stood inside an elevator and felt that subtle hum when it shifts between floors, you’ve experienced a small part of the system that keeps buildings moving— and behind that hum is a set of elevator power cables you never see. As someone who’s spent the last 12 years as an elevator power cable supplier, one of the most common questions I get from both building engineers and curious DIY types is this: “What’s the capacitance of an elevator power cable?” It’s not the sort of question that comes up when you’re choosing a cable for a garage door, but for elevators, it matters— a lot. Elevator Power Cable

Let’s start with what capacitance actually is, because too many people confuse it with voltage or current. At its most basic, capacitance is a measure of how much electrical charge a component can store when a certain voltage is applied. Any two conductors separated by an insulator (that’s called a dielectric) will have capacitance. For a standard power cable, the conductors are the copper wires carrying electricity, and the dielectric is the insulation around those wires, plus the space between them and the cable’s outer shield.

Elevator power cables are different from regular extension cords or building wiring, though. They’re flexible, designed to bend hundreds of thousands of times as the elevator moves up and down a shaft. Most have a core of insulated copper wires, wrapped in a layer of polymer insulation, then a metallic shield, and an outer jacket of durable rubber or plastic to stand up to dust, temperature swings, and occasional wear from elevator guide rails. That structure makes their capacitance unique— and it’s not a single number, either. Capacitance is measured in picofarads per foot (pF/ft) or picofarads per kilometer (pF/km), and it depends on a handful of factors that are specific to how we build elevator cables.

First, the spacing between conductors. The closer two copper wires are, the higher their capacitance, because the electric field between them is stronger. For standard power cables, conductors are often spaced just a few millimeters apart, but elevator cables need extra flexibility, so we don’t cram conductors as tightly. That might sound like a small detail, but it directly changes capacitance. Then there’s the thickness of the insulation: thicker insulation means conductors are farther apart, so capacitance goes down. We use a cross-linked polyethylene (XLPE) insulation for most elevator cables, which is durable and has a dielectric constant (the material’s ability to store charge) of around 2.3. That’s a bit lower than the PVC used in some cheaper cables, which usually has a dielectric constant of 3.4 to 3.8, so that cuts our capacitance right there.

Another big factor is the shield. Almost all elevator power cables have a metallic shield— usually copper tape or braided copper— that wraps around the core of conductors. The shield acts as a grounding layer, so it blocks electrical interference from other cables in the shaft, but it also adds a second conductor that’s very close to the core. That means we now have two sets of conductors to calculate capacitance between: the live and neutral wires inside the core, and each of those wires and the shield. That’s why elevator cables have a slightly higher overall capacitance than standard non-shielded power cables.

Now, let’s get to the numbers. For a typical 12-gauge elevator power cable— the size we use for standard 110V or 220V elevator systems— the capacitance is usually between 35 and 50 pF/ft. Wait, I know that sounds tiny— if you convert that to farads, that’s 35 trillionths of a farad per foot— but when you’re dealing with a cable that can be 1,000 feet long in a tall skyscraper, that adds up. A 1,000-foot cable would have a total capacitance of 35,000 to 50,000 pF, which is 0.035 to 0.05 microfarads. For comparison, a standard capacitor you’d pick up at a hardware store is usually a few microfarads, so this isn’t a huge number, but it’s enough to cause problems if you ignore it.

Let me explain why that capacitance matters for elevators. When the elevator controller sends a signal to move the car up, it sends voltage pulses through the power cable. If the cable has high capacitance, it acts like a sponge for that voltage: it stores the charge, so it takes longer for the voltage to rise and fall. That can slow down the elevator’s response time, make the controller less accurate, and even cause small glitches in the signal that lead to odd behavior— like the elevator stopping a foot too early at a floor, or making a slight jolt when it starts moving. For high-rise buildings, where elevator cables can be 1,500 feet long, that capacitance can jump to 60 pF/ft or more, so the problem gets even bigger.

I’ve seen this firsthand, too. A few years back, a building manager in Chicago reached out to us because their 80-story office building had elevator controllers that were acting erratic. They’d replaced the controllers multiple times, but the problem kept coming back. When we tested their existing cables, we found the capacitance was running at 58 pF/ft— way higher than the 45 pF/ft maximum the controller was designed to handle. The original cable manufacturer had used thinner insulation to save money, which made conductors closer together and pushed capacitance up. We swapped their cables for our standard high-flex elevator cables, which have thicker XLPE insulation and a precise shield spacing, and their capacitance dropped to 42 pF/ft. Within a week, their elevator controllers were working perfectly— no more glitches, no more service calls, and they saved almost $2,000 a year in maintenance costs. That’s the kind of impact capacitance can have.

You might be wondering: can I just ignore capacitance when choosing an elevator power cable? The short answer is no, not if you want a reliable system. If you’re a building engineer working on a new shaft, you need to check the controller’s specifications for maximum allowable capacitance, and pick a cable that stays under that number. If you’re replacing an old cable, you can test the old cable’s capacitance with a multimeter that has a capacitance setting— most modern multimeters do this easily— and match that number when you buy a new one. Don’t just grab any cable that fits the voltage rating; capacitance is a hidden specification that’s just as important.

Let’s talk about how we measure capacitance for our own cables, too, because that’s part of our job as suppliers. We don’t just pull a number out of thin air. We use a capacitance bridge, a tool that’s designed to measure small capacitances accurately, and we test each batch of cables right off the production line. We’ll take a 1-foot sample, strip off the jacket and shield, and measure the capacitance between two adjacent conductors, then do the same for a conductor and the shield. For our standard 12-gauge cables, we target 38 to 42 pF/ft, which is just under the 45 pF/ft mark most controllers recommend. For high-rise cables, we adjust the insulation thickness slightly to keep capacitance below 40 pF/ft even at 1,500 feet, because those long cables add so much charge-storing capacity.

There’s a common misconception that thicker cables have higher capacitance, but that’s not always true. A 10-gauge cable is thicker than 12-gauge, but if the insulation is the same thickness, the conductors are just a bit wider. Wait, wider conductors: does that affect capacitance? A little, actually. If two conductors are the same distance apart but one is thicker, the capacitance goes up a tiny bit— but it’s not a big difference. A 10-gauge cable might have a capacitance of 40 to 45 pF/ft, which is only 2 to 5 pF higher than 12-gauge. The bigger factor is still the insulation spacing and the shield. That’s why we don’t just make cables thicker for the sake of it; we adjust the insulation and shield to keep capacitance in the right range.

Another thing to keep in mind: temperature affects capacitance, too. Elevator shafts can get pretty hot in the summer, especially if the building’s HVAC system is working hard, and cold in the winter. When materials get warmer, their dielectric constant changes a little— XLPE’s dielectric constant goes up by about 0.02 for every 10 degrees Celsius, so a 20-degree temperature swing can change capacitance by 4 pF/ft. That’s not a huge shift, but it’s enough to push a cable that’s exactly within the maximum at 70 degrees over the limit when it’s 90 degrees outside. We test our cables at different temperatures to make sure their capacitance stays consistent, so our customers don’t have to worry about summer glitches.

I’ve had new installers ask me why we don’t just use coaxial cable for elevators, since coaxial has very precise capacitance. The problem is, coaxial cable isn’t flexible enough for elevator use. Elevators need cables that can bend 180 degrees every few seconds, thousands of times a year, and coaxial’s solid center conductor can crack if it’s bent too much. Our high-flex elevator cables are built with stranded copper conductors, which are made of hundreds of tiny wires that bend easily, so they can handle that repeated movement without breaking. That means we have to balance flexibility with the right spacing to keep capacitance low— it’s a tight line, but we’ve been perfecting it for decades.

Let’s circle back to that Chicago story, because it’s a perfect example of why this matters. The building manager had spent months troubleshooting, thinking the problem was the controller, the elevator motor, or even the guide rails. It never occurred to him that the cable he was using— which had worked for 20 years— was now the issue, because he’d replaced it with a cheaper cable that cut corners on insulation. That’s one of the reasons why we focus so much on capacitance in our cables: reliability isn’t just about voltage and current ratings. It’s about every small detail that adds up to a system that works every time someone presses a button to call an elevator.

If you’re in the market for an elevator power cable, I can’t stress enough that you should ask your supplier for the capacitance rating before you buy. A lot of suppliers will only give you the voltage and amp rating, but the good ones will have that capacitance number ready, and will explain how it fits with your elevator controller’s needs. Too many people learn this the hard way, like that Chicago building manager, when a small detail causes big problems.

For us, as elevator power cable suppliers, this isn’t just a technical number. It’s part of the promise we make to our customers: that their elevators will run smoothly, reliably, and safely, no matter how tall the building is, or how often the elevator moves. We test every batch, adjust our designs to balance flexibility and capacitance, and stand behind every cable we sell.

Whether you’re a building engineer working on a new high-rise, a maintenance manager replacing old cables, or just someone who’s ever wondered why elevators don’t get stuck halfway, the capacitance of elevator power cable is a small but critical piece of the puzzle. It’s not the first thing you think of when you look at an elevator, but it’s there, doing its job behind the scenes, keeping the cars moving up and down, floor after floor, all day long.

If you’re looking for elevator power cables that meet your capacitance needs, or want to learn more about how our cables are designed for reliable performance, we’re here to help. Reach out to us to discuss your specific requirements, whether you’re working on a small 10-story building or a skyscraper with dozens of elevators. We can help you choose the right cable, test its capacitance, and make sure your elevator system works as it should.

Data Cable References

  1. IEEE Standard for Electrical Power Cables for Elevators, IEEE Std 1107-2013
  2. ASTM D150, Standard Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical Insulation Materials
  3. Elevator Technology 11: Electrical and Control Systems, International Association of Elevator Engineers, 2019

Cixi Davos Wire & Cable Co., Ltd.
As one of the most professional elevator power cable manufacturers and suppliers in China, we also support customized service. Please feel free to buy bulk high quality elevator power cable in stock here from our factory. For price consultation, contact us.
Address: No.3, Lane 91, Ruan Ding Road, Linxi Village, Xiaolin Town, Cixi City